Product Line
Material
Standard
All Testing Machines
 | Angle meter for determining the deviation from squareness of insulation materials easy and precise.
| |
| AUT 11 |
| Weight | 100 kg |
| Picture text A | Autoclave 11 liters 16 bar |
| Supply Voltage | 230 V with ground, 50 Hz |
| Height | 800 mm |
| Width | 700 mm |
| Depth | 600 mm |
| Volume | 11 l |
| Max operating pressure | 16 bar |
| Heating element | 1.5 kW |
| Operating temperature | 10°C - 203°C |
| Con 6000 |
| Loadcell Capacity | 6000000 N |
| Weight | 6000 kg |
| Max stroke length | 300 mm |
| Daylight between columns | 750 mm |
| Vertical daylight | 600 mm |
| Frame stiffness | 6000 kN/mm |
| Resolution | 30.00 N |
| Supply Voltage | 3*400 V 50 Hz, max. 3 kW |
| Speed Range | 50 |
| CON-2CMT 200kN | CON-2CSP 250kN |
| Loadcell Capacity | 200000 N | 250000 N |
| Weight | | 300 kg |
| Max stroke length | | 300 mm |
| Daylight between columns | | 370 mm |
| Resolution | | 10.00 N |
| Supply Voltage | | 230 V 50 Hz. |
| DST 2,5N |
| Loadcell Capacity | 25 N |
| Weight | 40 kg |
| Supply Voltage | 230V 50Hz |
 | Based on the free-arm principle for testing sheets. | |
| FFT 5kN | FFT 30kN | FFT 50kN |
| Loadcell Capacity | 5000 N | 30000 N | 50000 N |
| Weight | 250 kg | 450 kg | 450 kg |
| Max stroke length | 200 mm |
| Free arm (frame dist) | 625 mm |
| Resolution | 0.05 N | 0.30 N | 0.50 N |
| Supply Voltage | 230 V or 115 V, 50-60 Hz |
| Speed Range | 300 |
| Force measuring error | Less than 1% of actual value from max. force down to 1/1000 of max. force |
| Loading speed control | Selectable load- or deflection speed. Programmable loading sequence for semiautomatic testing as well as automatic fast return. |
| Deformation resolution | 0.0100 mm |
| Control system | USB-connection to PC. The TRAM QA software makes the testing, filing and analysing of data extremely versatile - refer to the separate brochure for the software |
 | The Intelli-Jac series offers a range of highly flexible actuators which can be used with custom frames to test a very wide range of materials.
| |
| IJF 6/200 | IJF 6/500 | IJF 6/700 |
| Loadcell Capacity | 6000 N | 6000 N | 6000 N |
| Max stroke length | 200 mm | 500 mm | 700 mm |
| Daylight between columns | 500 mm |
| Frame stiffness | 5 kN/mm |
| Resolution | 0.06 N | 0.06 N | 0.06 N |
| Supply Voltage | 230V 50Hz or 115V 60Hz |
| Speed Range | 0.001-500 mm/min |
| Height | 890 mm |
| Width | 660 mm |
| Depth | 310 mm |
| Force measuring error | Less than 1% of actual value from max. force down to 1/1000 of max. force |
| Deformation resolution | 0.0010 mm |
| Control system | USB-connection to PC. The TRAM QA software makes the testing, filing and analysing of data extremely versatile - refer to the separate brochure for the software. |
 | The Intelli-Jac series offers a range of highly flexible actuators which
can be used with custom frames to test a very wide range of materials. | |
| ITJ20/500 |
| Loadcell Capacity | 20000 N |
| Weight | 32 kg |
| Max stroke length | 500 mm |
| Picture text A | Intelli-Jack 20 kN - without frame |
| Resolution | 0.10 N |
| Height | 1420 mm |
| Width | 400 mm |
| Depth | 170 mm |
| LTG 300 | LTG 400 |
| Free arm (frame dist) | 400 mm | 400 mm |
| Supply Voltage | 230 V 50 Hz or 115 V/60hz with ground. |
| Deformation resolution | 0.1000 mm | 0.1000 mm |
| Max thickness to be measured | 300 mm | 400 mm |
| MLG 160-210mm |
| Weight | 4 kg |
| Vertical daylight | 210 mm |
| Picture text A | MLG 160-210mm |
| Supply Voltage | Internal battery in Sylvac CS MFPM |
| Height | 400 mm |
| Width | 200 mm |
| Depth | 200 mm |
| Deformation resolution | 0.0010 mm |
| PCU 300-SA | PCU 300-DA |
| Weight | 100 kg | 100 kg |
| Picture text A | PCU 300 |
| Supply Voltage | 230 V, 50 Hz Standby: 14 W (excl. PC) Running: Typical 300 W, max 1500W |
| Height | 870 mm | 870 mm |
| Width | 700 mm | 700 mm |
| Depth | 300 mm | 300 mm |
| Control system | USB-connection to PC. The TRAM QA software makes the testing, filing and analysing of data extremely versatile - refer to the separate brochure for the software. |
| Max pressure | 300 bar | 300 bar |
| Max flow rate | 4.5 liter/min | 4.5 liter/min |
| Tank size | 15 liter | 15 liter |
| Valves | None | Direction valves |
| PIT 4 |
| Picture text A | Pendulum Impact Tester 4J |
| Supply Voltage | Via computer control system. |
| Control system | PC with MS Windows - and USB connection. |
| Impact energy | 4 Nm |
| Speed at impact | 3.3 m/sec. |
| Impact energy resolution | 0.001 Nm |
.jpg) | Pin penetrating thickness gauge for insulation materials | |
| PTG 20 | PTG 50 | PTG 250 | PTG 1000 |
| Picture text A | Pin Thickness gauge 20 Pa | Pin Thickness gauge 50 Pa.jpg | Pin Thickness gauge 250 Pa | Pin Thickness gauge 1000 Pa |
| Plate pressure | 20 Pa | 50 Pa | 250 Pa | 1000 Pa |
| Max thickness to be measured | 280 mm | 280 mm | 280 mm | 140 mm |
 |  |
 | | |
| RFT 20 | RFT 50 | RFT 100 | RFT 200 |
| Loadcell Capacity | 20000 N | 50000 N | 100000 N | 200000 N |
| Weight | 1500 kg |
| Max stroke length | 3000 mm |
| Daylight between columns | 1200 mm |
| Picture text A | RFT |
| Frame stiffness | 40 kN/mm | 100 kN/mm | 200 kN/mm | 400 kN/mm |
| Resolution | 0.20 N | 0.50 N | 1.00 N | 2.00 N |
| Supply Voltage | 230 V or 115 V, 50-60 Hz, with ground | 230 V or 115 V, 50-60 Hz, with ground | 230 V or 115 V, 50-60 Hz, with ground | 3*400/230 V, 50-60 Hz, with ground |
| Speed Range | 0.001mm/min - 300mm/min as standard |
| Loading speed control | Selectable load- or travelling speed. Programmable loading sequence for semiautomatic testing as well as automatic fast return. |
| Deformation resolution | 0.0100 mm |
| Control system | USB-connection to PC. The TRAM QA software makes the testing, filing and analysing of data extremely versatile - refer to the separate brochure for the software. |
 |  |
 | | |
| SUT 3000/325 | SUT 3000/520 | SUT 3000/1000 | SUT 5000/520 |
| Loadcell Capacity | 3000 N | 3000 N | 3000 N | 5000 N |
| Weight | 40 kg | 40 kg | 45 kg | 45 kg |
| Max stroke length | 325 mm | 520 mm | 3000 mm | 520 mm |
| Free arm (frame dist) | 66 mm |
| Picture text A | SUT 3000N / 520mm |
| Resolution | 0.02 N | 0.02 N | 0.02 N | 0.05 N |
| Supply Voltage | 220/240 V or 110/120 V, 50-60 Hz |
| Speed Range | 1-500 mm/min as standard |
| Height | 941 mm | 1036 mm | 1518 mm | 1516 mm |
| Width | 300 mm |
| Depth | 390 mm |
| Loading speed control | Servo controlled travelling speed. |
| Control system | The machine can operate on its own - without any connection to a PC. The machine can also be supplied in a Professional Version where the advanced TramQA software makes almost any testing and reporting fully automatic. - refer the separate Tram-QA brochure. |
 | Tensile tester for insultation.
| |
| TEN 1000N | TEN 2000N | TEN 5000N |
| Loadcell Capacity | 1000 N | 2000 N | 5000 N |
| Weight | 75 kg |
| Max stroke length | 500 mm |
| Daylight between columns | 600 mm |
| Resolution | 0.01 N | 0.02 N | 0.05 N |
| Supply Voltage | 220/240 V or 110/120 V, 50-60 Hz |
| Deformation resolution | 0.0100 mm |
| Control system | USB-connection to PC. The TRAM QA software makes the testing, filing and analyzing of data extremely versatile - refer to the separate brochure for the software. |
 | The UCT is a very versatile machine designed to deliver superior results in terms of precision in deflection and force measurement. The fully automated testing system delivers the fastest and easiest workflow for the operator.
| |
| UCT 10kN | UCT 50kN | UCT 300kN |
| Loadcell Capacity | 10000 N | 50000 N | 300000 N |
| Weight | 145 kg | 155 kg | 850 kg |
| Daylight between columns | 450 mm |
| Vertical daylight | 650 mm | 650 mm | 1300 mm |
| Picture text A | UCT 50kN | UCT 50kN | UCT 200kN |
| Picture text B | UCT 50kN with secondary testingspace |
| Frame stiffness | 50 kN/mm | 50 kN/mm | 200 kN/mm |
| Resolution | 0.05 N | 0.25 N | 1.50 N |
| Supply Voltage | 230V 50Hz or 115V 60Hz |
| Speed Range | 0.001mm/min - 500mm/min | 0.001mm/min - 500mm/min | 0.0005mm/min - 200mm/min |
| Height | 1260 mm | 1260 mm | 2340 mm |
| Width | 750 mm | 750 mm | 1040 mm |
| Depth | 310 mm | 310 mm | 700 mm |
| Force measuring error | Less than 1% of actual value from max. force down to 1/1000 of max. force |
| Second testing space | Optional second testing space above the travelling beam |
| Addistional sensors | Optional Thickness gauge, Extensometer, extra loadcells, balance etc. can be connected |
| Loading speed control | Selectable load- or travelling speed. Programmable loading sequence for semiautomatic testing as well as automatic fast return. |
| Deformation resolution | 0.0001 mm |
| Control system | USB-connection to PC. The Tram-QA software makes the testing, filing and analysing of data extremely versatile - refer to the separate brochure for the software |
 |  |
 | The UCT Wide is a very versatile machine designed with a wider loadbeam to deliver superior results in terms of precision in deflection and force measurement. The fully automated testing system delivers the fastest and easiest workflow for the operator. | |
 |  |
 | | |
| UTM 400kN | UTM 600kN | UTM 1000kN | UTM 2000kN |
| Loadcell Capacity | 400000 N | 600000 N | 1000000 N | 2000000 N |
| Weight | 1000 kg | 1200 kg | 3000 kg | 5000 kg |
| Max stroke length | 200 mm | 250 mm | 250 mm | 250 mm |
| Daylight between columns | 500 mm | 600 mm | 700 mm | 750 mm |
| Vertical daylight | 750 mm | 800 mm | 850 mm | 900 mm |
| Resolution | 4.00 N | 6.00 N | 10.00 N | 20.00 N |
| Supply Voltage | 230V 50 Hz, max. 2.1 kW | 230V 50 Hz, max. 2.1 kW | 3*400 V 50 Hz, max. 4,5 kW. | 3*400 V 50 Hz, max. 4,5 kW |
| Speed Range | 0.1mm/min - 150mm/min | 0.1mm/min - 100mm/min | 0.1mm/min - 80mm/min | 0.1mm/min - 40mm/min |
| Height | 3000 mm |
| Force measuring error | Error on force is less than 1% in the range from 0.45kN to 400kN | Error on force is less than 1% in the range from 1kN to 600kN | Error on force is less than 1% in the range from 1kN to 1000kN | Error on force is less than 1% in the range from 2kN to 2000kN |
| Loading speed control | Selectable load-speed (kN/min) or deformation speed (mm/min). Programmable testing sequence for semiautomatic testing as well as automatic fast return. |
| Deformation resolution | 0.0100 mm |
| Control system | USB-connection to PC. The TRAM QA software makes the testing, filing and analysing of data extremely versatile - refer to the separate brochure for the software. |